Description

Overview

SPX FLOW APV Delta D4 and D4 SL double-seat mixproof valves (from the manufacturer English manual) separate two incompatible line passages using two balanced, independently operating valve shafts with an intervening depressurized leakage chamber (L). Protected against pressure hammer, the valve opens from top to bottom in a low-leakage design and resets to the safe closed position via spring force.

Standard D4 valves use a non-seat-lift actuator with a CU41 control unit (H336954 6 mm / H336959 1/4” OD), while D4 SL valves feature upper and lower seat-lift actuation paired with a CU43 control unit (H336955 6 mm / H336960 1/4” OD). Both variants include a polypropylene CIP spray connection (C) for cleaning the leakage chamber at 2–5 bar.

Features

  • Balanced upper and lower valve shafts prevent pressure hammer and separate incompatible liquids safely
  • Vertical installation enables free gravity drainage through the depressurized drain pipe (E)
  • Completely removable valve insert permits direct orbital TIG welding of the housing into the pipeline
  • D4 SL independent upper (port 2) and lower (port 3) seat lifting at 2–5 bar cleaning pressure
  • Compatible with CU4 Direct Connect, AS-interface, M12, and CU4plus control units (H337098 / H336441 adapters) or 10–30 V DC inductive proximity switches (H16223 / H16432)

Technical Data

ParameterSpecification
Product-wetted parts1.4404 / 316L (DIN EN 10088)
Other parts1.4301 (DIN EN 10088)
Seals (DN40–100 / 1,5”–4”)EPDM standard; HNBR, FPM optional
Seals (DN125–150 / 6”)EPDM/PTFE compound standard; HNBR/PTFE, FPM/PTFE optional
Max. line pressure10 bar
Max. operating temperature135 °C (EPDM, HNBR; FPM no steam); short-term 140 °C; CIP > DN100 up to 100 °C
Air connection & pressure6 x 1 mm or 1/4” OD; 5 bar min. to 8 bar max. (ISO 8573-1 class 3/3/1)
CIP spray connection (PP)8 x 1 mm (DN40–100) / 10 x 1 mm (DN125–150); 2–5 bar
Tightening torque10 Nm (stop sleeve), 40 Nm (shaft safety nuts)

Dimensions, Weights and Kvs Values (D4 Standard Valve)

SizeA (mm)A1 (mm)B (mm)Ø Da (mm)Ø Di (mm)F (mm)H (mm)L (mm)L1 (mm)X* (mm)Y* (mm)Weight w/ CU (kg)Kvs Max (m³/h)
DN4048356612041381256366674971020014,949
DN5048757012653501257568877174021815,094
DN6549557813470661259172080378024216,6170
DN805836661468581142,510683591889027425,5211
DN100593676156104100142,512587495794030325,9369
DN12567776017912912515015010061089103035041,0588
DN15072579319415415015017510941162107539049,0844
1,5”48356611938,134,81256366775071019914,943
2”48757012550,847,61257568877174021715,087
2,5”49557813163,560,312585,3708,3791,376023415,7156
3”58366613776,172,912597,9732,9815,979025216,1192
4”593676155101,697,6142,512587495794030225,3359
6”727794193152,4146,915017510951162108039049,0808

* X = minimum installation and valve insert removal height (without CU4; X1 adds CU4 clearance). D4 SL seat-lift variants weigh 15,5–53,5 kg with A = 524–727 mm.

Air Consumption and Switching Times (at 5 bar)

SizeD4 Air (NL/stroke)D4 Open / Close (s)D4 SL Air Main / Upper / Lower (NL)D4 SL Open / Close (s)
DN40 / 1,5”1,61,0 / 1,41,5 / 3,4 / 0,221,5 / 1,7
DN50 / 2”1,81,1 / 1,71,7 / 3,4 / 0,221,5 / 1,7
DN65 / 2,5”–3”21,7 / 2,01,8–2 / 3,4 / 0,221,6–1,7 / 1,9–2,0
DN80–100 / 4”3,72,6 / 3,33,7 / 7,7 / 0,222,6 / 3,3
DN1255,53,4 / 5,25,5 / 10,5 / 0,223,4 / 5,2
DN150 / 6”8,63,5 / 9,38,6 / 16,5 / 0,743,5 / 9,3

Ordering Information

When ordering SPX FLOW APV Delta D4 or D4 SL valves, share the APV part code or specify version (D4 or D4 SL), line size (DN40–DN150 or 1,5”–6”), body port configuration, elastomer type (EPDM, HNBR, FPM), and CU4 control unit interface.