Description
Overview
SPX FLOW APV Delta SW4 (from the manufacturer English manual) is a pneumatic single-seat shut-off and change-over valve engineered for brewing, beverage, dairy, food, chemical, and pharmaceutical processing lines. The valve operates by compressed air on a maintenance-free actuator and resets via spring force, configurable as NC (normally closed, air-to-raise / spring-to-lower) or NO (normally open, air-to-lower / spring-to-raise).
Standard valves are equipped with a CU41 Direct Connect control unit (08-45-100/93; H320460), with AS-interface extended (08-45-110/93; H320467), IO-Link (08-45-481/93; H345124), or proximity switch holder (08-60-011/93; H16223) options.
Features and Options
- Completely dismantlable valve insert; weld-end housings weld directly into the line (except SWE41/SWE42 lower clamp housing, and detachable clamp/flange upper housing on change-over valves)
- Optional pneumatic stroke limitation (0–100% continuous adjustment on NC design using
CU43-S-2 Hall sensors-Direct Connect,H320466) - Optional oil dampening cylinder between actuator and control unit to slow opening/closing and avoid pressure hammer
- Family variants include SW4 DN125–150, manual actuation, SWT4 tank outlet valve, long stroke, SW4-DPF (with steam chamber), SWR4 (modulating cone), and SW4 ATEX (DN25–100, 1”–4”)
Technical Data
| Parameter | Specification |
|---|---|
| Product-wetted parts | 316L / 1.4404 (DIN EN 10088) |
| Other parts | 1.4301 (DIN EN 10088) |
| Standard seal / options | EPDM standard; HNBR, FPM, VMQ optional |
| Max. line pressure | 10 bar (actuator-dependent product pressure per sizing table) |
| Max. operating temperature | 135 °C (EPDM, HNBR; FPM/VMQ no steam); short-term 140 °C |
| CIP cleaning liquid (> DN100/4”) | Up to 100 °C |
| Pneumatic air connection | 6 x 1 mm hose; 6 bar min. to 8 bar max. |
| Compressed air quality (ISO 8573-1) | Solid class 3; water class 3 (-20 °C dew point); oil class 1 (max. 0,01 mg/m³) |
| Actuators (air consumption @ 6 bar) | Ø 74 mm (1,0 NL/stroke); Ø 110 mm (2,1 NL/stroke); Ø 165 mm (4,5 NL/stroke) |
Dimensions, Weights, Stroke and Kvs (Single-Seat Weld-End Housing)
| Size | A (mm) | L (mm) | Ø Di (mm) | F (mm) | Ø G (mm) | H (mm) | Ø K (mm) | A1 (mm) | L1 (mm) | Stroke SW41/42 (mm) | Kvs SW41/42 (m³/h) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DN25 | 410 | 460 | 26 | 50 | 18 | 54 | 86 | 338 | 388 | 12 | 20 / 21 | 5 |
| DN40 | 414 | 481 | 38 | 67 | 24 | 66 | 86 | 342 | 409 | 25 | 45 / 53 | 5 |
| DN50 | 451 | 523 | 50 | 72 | 32 | 78 | 126 | 379 | 451 | 28 | 92 / 85 | 7 |
| DN65 | 459 | 544 | 66 | 85 | 40 | 94 | 126 | 387 | 472 | 28 | 159 / 159 | 7 |
| DN80 | 512 | 610 | 81 | 98 | 47,5 | 109 | 189 | 440 | 438 | 28 | 201 / 209 | 13 |
| DN100 | 522 | 633 | 100 | 111 | 57 | 128 | 189 | 450 | 561 | 28 | 302 / 325 | 15 |
| 1” | 408 | 458 | 22,6 | 50 | 16,3 | 50,6 | 86 | 336 | 386 | 12 | 16 / 18 | 5 |
| 1,5” | 412 | 479 | 34,9 | 67 | 22,4 | 62,9 | 86 | 340 | 407 | 25 | 38 / 45 | 5 |
| 2” | 450 | 522 | 47,6 | 72 | 30,8 | 75,6 | 126 | 378 | 450 | 28 | 83 / 77 | 7 |
| 2,5” | 456 | 541 | 60,3 | 85 | 37,2 | 88,3 | 126 | 384 | 469 | 28 | 133 / 133 | 7 |
| 3” | 507 | 597 | 72,9 | 90 | 43,5 | 100,9 | 189 | 435 | 525 | 28 | 176 / 176 | 13 |
| 4” | 520 | 631 | 97,6 | 111 | 55,8 | 125,6 | 189 | 448 | 559 | 28 | 292 / 310 | 15 |
Change-over valve variants (SW43 / SW44) weigh 6 kg (DN25–40), 8 kg (DN50–65), 15 kg (DN80 / 3”), and 17 kg (DN100 / 4”) with strokes of 9, 22, and 25 mm.
Calculatory Product Pressures (bar at 6 bar Air Pressure, SW41 FS)
| Size | Ø 74 mm | Ø 110 mm | Ø 165 mm |
|---|---|---|---|
| DN25 / 1” | 11,7 | — | — |
| DN40 / 1,5” | 5,0 | 12,5 | — |
| DN50 / 2” | 2,8 / 2,0 | 7,6 / 5,4 | 19,6 / 13,8 |
| DN65 / 2,5” | 1,7 | 5,0 | 11,7 |
| DN80 / 3” | — | 3,1 / 3,8 | 7,9 / 9,9 |
| DN100 / 4” | — | 2,1 | 5,3 |
Ordering Information
When ordering SPX FLOW APV Delta SW4 valves or OEM seal kits, specify housing type (single-seat or change-over), line size (DN25–DN100 or 1”–4”), actuator size/action (NC or NO), seal material (EPDM, HNBR, FPM, VMQ), and CU4 control unit protocol.